LEFOO Clamp Type Sanitary Flat Film Pressure Transmitter LFT2020 | |||||
Measurement Range | -100Kpa…0~10KPa…7MPa | ||||
Overload Pressure | 1.5 time of full scales | ||||
Accuracy | ±0.5%F.S.,±1.0%F.S. | ||||
Stability | <0.5%F.S./Year | ||||
Working Temperature | -20~+85℃ | ||||
Medium Temperature | -40~+100℃/-40~+150℃ | ||||
Medium | All corrosive mediums can be compatible with 316 stainless steel, Fluoroelastomer or NBR. | ||||
LEFOO General Type Clamp Type Sanitary Flat Film Pressure Sensor LFT2020 | |||||
Electrical properties | Two-wired | Three-wired | Four-wired | ||
Output Signal | 4~20mA | 0.5~4.5V | 0~10V | RS485 | |
Power Supply | 10~36VDC | 4.75~5.25VDC | 12~36VDC | 10~30VDC | |
Electrical Connection | DIN43650A (Big Hirschmann), M12 waterproof outlet, GX12 aviation connector (three cores/four cores), M12 four-core aviation connector | ||||
LEFOO Explosion-proof Type Clamp Type Sanitary Flat Film Pressure Sensor LFT2020 | |||||
Electrical properties | Two-wired | Three-wired | Four-wired | ||
Output Signal | 4~20mA | 0~10V | RS485 | ||
Power Supply | 10~30VDC | 14~36VDC | 10~36VDC | ||
Electrical Connection | Directly outlet | ||||
Protection Class | IP65 | ||||
Pressure Connection | 50.5mm clamp | ||||
Pressure Form | Gauge Pressure G/Absolute Pressure A | ||||
Certification | EU electrical safety standards CE |
Code and Description | Remark | |||||||||||
LFT2020 | Clamp Type Sanitary Flat Film Pressure Sensor | Model | ||||||||||
Range | -100Kpa…0~10KPa…7MPa | Range | ||||||||||
A4 | A4 = 4~20mA(Two-wired) | Output mode | ||||||||||
V05 | V05 = 0.5~4.5V(Three-wired) | |||||||||||
V0 | V0 = 0~5V(Three-wired) | |||||||||||
V10 | V10 = 0~10V(Three-wired) | |||||||||||
RS | RS485 = RS485(Four-wired) | |||||||||||
K | K = kpa | Unit | ||||||||||
P | P = psi | |||||||||||
B | B = bar | |||||||||||
M | M = Mpa | |||||||||||
0.5 | 0.5= ±0.5%F.S. | Accuracy | ||||||||||
1.0 | 1.0= ±1.0%F.S | |||||||||||
D1 | D1 = DIN43650A Big Hirschmann | Electrical connection | ||||||||||
M | M = M12 Waterproof outlet | |||||||||||
C3 | C3 = GX12 three cores aviation connector | |||||||||||
C4 | C1 = GX12 four cores aviation connector | |||||||||||
H | H = M12 four cores aviation connector | |||||||||||
K2 | K2=50.5mm clamp | Pressure connection | ||||||||||
N | Without display | Display | ||||||||||
D1 | General digital display type | |||||||||||
D2 | Explosion-proof digital display type | |||||||||||
1.0 | 1.0 = 1m | Cable Lenth | ||||||||||
2.0 | 2.0 = 2m | |||||||||||
LFT2020 | 0-10 | A4 | B | 1.0 | D1 | K2 | N | 1.0 | Selection Example |